INSTRUCTIONS-PARTS LIST
Husky 515
308666
55-Gallon Dispenser Package
Rev. C
This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
INSTRUCTIONS
100 psi (6.9 bar) Maximum Air Input Pressure
Model 231418, Series B
Dispense Package with Gun
Model 231419, Series B
Dispense Package
Table of Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Parts Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parts Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Service and Technical Data . . . . . . . . . . . . . . . . . . . . . . 7
Dimensional Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Graco Phone Number . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
9294A
Model 231418 shown
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
D Ground all equipment and the equipment being dispensed to. Refer to Grounding on page 6.
D If there is any static sparking or you feel an electric shock while using this equipment, stop dis-
pensing immediately. Do not use the equipment until you identify and correct the problem.
D Do not use kerosene or other flammable solvents or combustible gases to flush the unit.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being dispensed.
D Keep the dispensing area free of debris, including solvent, rags, and gasoline.
D Do not smoke in the dispensing area.
D Extinguish all open flames and pilot lights in the dispensing area.
MOVING PARTS HAZARD
Moving parts, such as the rotating blades of the agitator, can pinch or amputate your fingers or other
body parts and can cause splashing in the eyes or on the skin.
D Keep clear of all moving parts when starting or operating the agitator.
D Always shut off the agitator and disconnect the air line before you remove the agitator from the
drum or check or repair any part of the agitator.
D Do not operate the agitator while an air line is hooked up to the elevator air fitting. Such operation
could cause the agitator blades to turn while the elevator is raised, which could result in serious
bodily injury or damage to the equipment from the hose getting tangled in the rotating agitator
blades.
TOXIC FLUID HAZARD
Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the
skin, swallowed, or inhaled. When flushing the air motor or pump, keep your face away from the
exhaust port.
308666
3
Parts Drawing
Husky 515 55-Gallon Dispense Package with Gun, Model 231418, Series B
Includes items 1 through 54
Husky 515 55-Gallon Dispense Package, Model 231419, Series B
Includes items 1 through 26
27
50
restrictor
valve
24
1 1
51
14
52
13
53
54
18
agitator
7
needle
valve
8
9
6
17
15
20
23
19
18
4
4
10
12
3
3
1
2
3
Husky 515 Diaphragm Pump
(see manual 308981)
21
22
Drum Cover Assembly
(see manual 308466)
16
Siphon Kit
(see manual 308609)
2
2
11
elevator
air control
valve
4
5
Elevator Assembly
(see 306287)
24
Heavy-Duty SST Drum Agitator
(see manual 308609)
25
5
5
9295A
3
3
4
308666
Parts List
Husky 515 55-Gallon Dispense Package with Gun, Model 231418, Series B
Includes items 1 through 54.
Husky 515 55-Gallon Dispense Package, Model 231419, Series B
Includes items 1 through 26.
Ref
No.
Ref
No.
Part No. Description
Qty.
Part No. Description
Qty.
1
2
3
4
5
241564
238283
238250
237746
238157
PUMP, Husky 515, acetal
14
15
16
17
18
19
20
21
22
23
24
25
27
50
51
52
53
54
100022
108094
111821
111280
156971
110223
108865
100721
169971
155541
203266
208536
110733
158212
238740
237607
168683
161505
SCREW, cap
NUT, lock
SCREW, mach, hex head
NUT, locking
NIPPLE, short
BALL VALVE, vented
SCREW, mach, pan head
PLUG, pipe, headless
FITTING, air line
UNION, swivel; 90_
HOSE, coupled
COUPLER, air line
ELBOW, 45_, 1/4 npt
BUSHING, pipe
HOSE, coupled, conductive
FLOW GUN, severe duty
BUSHING, nozzle
NOZZLE, flow gun
4
4
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
See manual 308981.
DRUM COVER ASSEMBLY
See manual 308466.
SIPHON KIT
See manual 308609.
ELEVATOR ASSEMBLY
See manual 306287.
DRUM AGITATOR, heavy duty;
SST See manual 308609.
BRACKET, pump
UNION, suction tube
NUT, union, swivel
O-RING, packing
REGULATOR, air
BLOCK, diverter
1
1
1
1
1
1
1
1
1
1
1
1
4
6
7
8
9
10
11
12
13
191565
191566
191567
113575
111804
111805
108190
100086
GAUGE, air pressure
WASHER, plain
308666
5
Installation
Mounting the Elevator Base to the Floor
Grounding
WARNING
You must mount the elevator base to the floor
before you operate this equipment.
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, the mounting
cover and all electrically conductive objects or devices
in the dispensing area must be properly grounded.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.
1. Position the elevator where there is at least 9 feet
(2.75 meters) of overhead clearance.
2. Mark and drill holes in the floor for 0.5-in. (13 mm)
mounting bolts. See the mounting layout in the
Dimensional Drawing on page 7.
3. Level the elevator base, using shims if necessary,
and bolt the base firmly to the floor.
To ground the dispenser, connect the end of the
ground wire to a true earth ground.
Operation
4. Using the needle valve on the agitator to adjust the
agitator speed, gradually increase the speed until
you can see (through the inspection port in the
drum cover) movement in the surface of the liquid,
but do not increase the agitator speed enough to
create a vortex in the surface of the liquid. If the
surface begins to vortex, decrease the agitator
speed to prevent air entrainment.
WARNING
MOVING PARTS HAZARD
To reduce the risk of serious injury,
including cuts, amputation of fingers by
the agitator blades, and splashing in
the eyes or on the skin, always shut off the
agitator (disconnect the air line from the agitator)
before you raise, check, or repair the agitator.
NOTE: Always maintain moderate agitator speed,
which is approximately 50 rpm of the agitator
blades. Excessive agitator speed may cause
vibration, foaming of fluid, and increased wear on
parts. Always agitate fluid thoroughly before
supplying it to the dispensing equipment, and
continue agitating fluid while the dispensing equip-
ment is being supplied.
Never operate the agitator when the elevator is
raised. See Moving Parts Hazard on page 3.
Startup
See the Parts Drawing on page 4.
5. Use the regulator (10) and ball valve (19) to control
the pressure and operation of the pump (1).
1. Flush the dispenser before first use.
NOTE: The pump was tested in water. To elimi-
nate possible contamination of the fluid you are
pumping, before you use the dispenser, flush the
pump thoroughly with a solvent compatible to the
solvent you are dispensing.
6. Raise or lower the elevator by pulling out or push-
ing in the air control valve (a push-pull handle) on
the rim of the drum cover. Normal operation
requires only a few seconds for air pressure to
build up and raise the elevator or to exhaust and
lower the elevator.
2. Ensure that the needle valve on the agitator is
closed and that the dispenser ball valve (19) is
closed.
NOTE: To increase the operating speed of the
elevator, loosen the hex nut on the restrictor valve,
and turn the valve needle out. To decrease the
operating speed, turn the valve needle in. The
restrictor valve is on the top of the elevator, as
shown in the Parts Drawing.
3. Connect the air supply line to the male air line
fitting (22).
6
308666
Service and Technical Data
See the individual component instruction manuals for service instructions and technical data.
Dimensional Drawing
NOTE: See individual component instruction manuals for dimensions
of agitator, pump, elevator, siphon kit, and drum cover.
Elevator Base
Mounting Hole Layout
height of unit from
base to top of pump
when elevator is raised
8.88 in.
(225.6 mm)
95 in.
(2413 mm)
5.5 in.
(140 mm)
0.56-in.
(14.2 mm)
holes
25.9”
57 in.
(1448 mm)
9294A
35.62”
33.75”
ti22759a
308666
7
The Graco Warranty and Disclaimers
WARRANTY
Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on
the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of
this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven
defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s writ-
ten recommendations.
This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation,
misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-
Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco
equipment of structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, instal-
lation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor
for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any
defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts,
labor and transportation.
DISCLAIMERS AND LIMITATIONS
The terms of this warranty constitute purchaser’s sole and exclusive remedy and are in lieu of any other warranties (express or
implied), including warranty of merchantability or warranty of fitness for a particular purpose, and of any non-contractual
liabilities, including product liabilities, based on negligence or strict liability. Every form of liability for direct, special or consequen-
tial damages or loss is expressly excluded and denied. In no case shall Graco’s liability exceed the amount of the purchase
price. Any action for breach of warranty must be brought within two (2) years of the date of sale.
EQUIPMENT NOT COVERED BY GRACO WARRANTY
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose, with
respect to accessories, equipment, materials, or components sold but not manufactured by Graco. These items sold, but not
manufactured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer.
Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
Graco Phone Number
TO PLACE AN ORDER, contact your Graco distributor, or call to identify the distributor closest to you:
Phone: 6126236921 or Toll Free: 1--800--328--0211 Fax: 612--378--3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 308666.
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES P.O. BOX 1441 MINNEAPOLIS, MN 55440--1441 USA
ECOPYRIGHT 1996, GRACO INC. All Graco manufacturing locations are registered to ISO 9001.
Revision C, January 2014
8
308666
|